Case study

Every new asset expired on arrival

Nexio ingest started assigning a 1969 kill date to new media. How I narrowed it down and escalated it with clean evidence.

Owner-reported findings. Published Oct 26, 2026. Reviewed Oct 26, 2026.

Symptom

Every new asset ingested into Nexio showed up already expired, with a kill date in 1969.

A 1969 date is a hint in itself: it usually means a timestamp of zero or “empty” being read as a date near the Unix epoch.

What I checked

  1. Compared MXF files with MediaInfo, a working file against a failing one, to see whether the media itself carried something different.
  2. Checked timestamps on the files and the systems involved.
  3. Rebooted the MOS gateway, since the kill date passes through it.

Escalation

With those checks done, I escalated to the vendor with clean evidence: what was happening, when it started, what a good file and a bad file looked like, and what I’d already ruled out. The format I use is in What to send a vendor.

Takeaway

You don’t have to find the root cause to make a vendor case move fast. You have to show them where it isn’t.